Mixing Ratio
| Accelerator Solution | Accelerator : Water | variable, see Metering Chart below |
| APremix | Accelerator Solution : Component A (Resin) | 2 L per 8 kg of Component A (Resin) |
| BHardener Solution | Hardener powder : Water | 80 g (2 × 40 g) per 10 L of water |
| Sika® Injection-306 | APremix : BHardener Solution | 1 : 1 by volume |
Note for processing in one component pumps:
Workability time (pot life) = Reaction time (see metering chart) – 10 minutes
Accelerator Metering Chart
| ml Accelerator1 | Ambient Temperature |
| Reaction time | 5 °C (41 °F) | 10 °C (50 °F) | 20 °C (68 °F) | 30 °C (86 °F) | 40 °C (104 °F) |
| 8 min | | | 2000 2 | 980 2 | 380 |
| 10 min | | | 1150 2 | 480 | 240 |
| 12 min | | 1880 2 | 820 2 | 320 | 180 |
| 15 min | 1800 2 | 1240 2 | 480 | 220 | 100 |
| 20 min | 1060 2 | 900 2 | 280 | 140 | 60 |
| 25 min | 820 2 | 480 | 200 | 80 | |
| 30 min | 620 2 | 350 | 160 | | |
| 35 min | 440 | 280 | 120 | | |
| 40 min | 360 | 250 | 80 | | |
| 45 min | 320 | 220 | 78 | | |
| 50 min | 250 | 200 | 74 | | |
- Quantity of Accelerator per 8 kg component A to, yield of 20 liters kg mixed resin (the Total Accelerator solution must be 2000 ml 2 liters – see example below).
- Fast reaction – additional accelerator necessary.
Example:
Ambient temperature: 10 °C (50 °F)
Required reaction time: 25 min
Accelerator in ml = 480 ml
Water in ml = 1520 ml
Total volume = 2000 ml
Note:
The given data are laboratory parameters and may deviate depending on the object and conditions on site.